 120-960 Watts
ADN Series
3-Phase
Total Power: 120 - 960 Watts Input Voltage: 1O or 3O 380-480 VAC # of Outputs: One
Electrical Specs
Input
Nominal voltage Power factor (PFC) AC Input range DC Input range Frequency Phase 380-480 VAC EN61000-3-2 340-576 VAC 450-820 VDC 47 - 63 Hz, 500 Hz 1O or 3O on 5, 10 & 20A* models. 30A & 40A models are 3O only.
Output
24V (22.5 - 28.5 VDC Adj.) >20ms at full load (25C) <2% overall (combination line/load/time/temp) Line regulation <0.5% Load regulation <0.5% Time & temp. drift <1% Initial voltage setting 24.5V 1% Ripple <50mVpp Parallel Operation Current limit (fold forward) constant power 10A, 20A, 30A User selectable 40A Active single wire parallel Over voltage protection >30.5 <33 VDC *On 20A unit, derate to 75% when operating 1O. Nominal voltage Holdup time Tolerance
Special Features
*Complies with EN61000-3-2 *DC OK Signal (indicator) *Adjustable Voltage *Industrial grade design (no derating to 60C) *User-friendly front panel *Single phase input available *Highly efficient >90% switching technology *High MTBF and reliability *Peak current capability 2x rated current for 2 seconds *Three year warranty
Safety
EMC Emissions EN500081-1, -2 Class B EN55011, EN55022 Radiated and Conducted including Annex A. EN50082-1, -2; EN61000-4-2, Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3; EN61000-4-4 Level 4 input and Level 3 output; EN61000-4-5 Isolation Class 4, EN61000-4-11; Transient resistance according to VDE 0160/W2 over entire load range. CB Scheme, EN60950; EN50178; EN60204; UL508 Listed, cULus; UL60950, cRUus, CE (LVD 73/23 & 93/68/EEC) EN61000-3-2, IEC 6007915 Class 1, Zone 2 hazardous location, Groups IIA, IIB, IIC w/T3 temp class up to 60C Ambient. Class 1 (IEC536), degree of protection SELV rated per EN60950
Environmental
Storage/shipment Operating (convection) Humidity -25C to +85C -10C to 60C (derate to 50% at +70C) <90% RH noncondensing per IEC 68-2-2, 68-2-3 IP20 (EN60529), protection from moisture & condensation
Immunity
Approvals
Note: Derate output to 50% when unit is mounted sideways or front side up.
Protection
190
Technical Support: (888) 41ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
rev 03.25.05
AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698
EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355
ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426
ADN Series
Ordering Information
Model ADN5-24-3PM ADN10-24-3PM ADN20-24-3PM ADN30-24-3PM ADN40-24-3PM Weight 1.7lbs (730g) 2.16lbs (980g) 3.97lbs. (1800g) 4.0lbs (2000g) 6.6lbs (3300g) Power 120W 240W 480W 720W 960W Input Voltage 380-480VAC 380-480VAC 380-480VAC 380-480VAC 380-480VAC Current 5A 10A 20A 30A 40A
Catalog Number ADN5-24-3PM
Dimensions - inches (mm) H 4.88 (124) W 2.91 (73) D 4.55 (116)
Catalog Number ADN10-24-3PM ADN20-24-3PM ADN30-24-3PM ADN40-24-3PM
Dimensions - inches (mm) H 4.88 (124) 4.88 (124) 4.88 (124) 4.88 (124) W 3.50 (89) 5.90 (150) 9.72 (247) 11.10 (282) D 4.55 (116) 4.55 (116) 4.55 (116) 4.55 (116)
Installation Fusing -Input -Output Internally fused. Outputs are capable of providing high currents for short periods of time for inductive load startup or switching. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated. Continuous current overload allows for reliable fuse tripping. Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDNPMBRK2 required). Input: IP20-rated screw terminals, connector size range: 16-10 AWG (1.5-6 mm2) for solid conductors. 16-12 AWG (0.5-4 mm2) for standard conductors. Output: Two connectors per output, connector size range: 16-10 AWG (1.5 - 6mm2) for solid conductors. Fully enclosed metal housing with fine ventilation grid to keep out small parts. 25mm above and below 25 mm left and right 15 mm in front 70 mm above and below 25 mm left and right 15 mm in front
Mounting
Connections Case -Free Space
www.astecpower.com
191


▲Up To Search▲   

 
Price & Availability of ADN10-24-3PM

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X